MAG Systems, Inc.
|
|
|
Analytical Technology's newest product is their A15/66 Residual Sulfite Monitor. You can call this a dechlorination analyzer. This product may be revolutionary since it accurately measures sulfite in parts per million of a wastewater plant's effluent. Plants who dechlorinate with sulfur dioxide or sodium bisulfite tend to over-sulfonate in order to avoid the fines associated with discharging chlorinated water. This analyzer will allow you trim your sulfination down and save cost. The A15/66 uses a unique and patented "gas-phase" sensor to make the sulfite measurement. Since the sensor never touches the process, it never gets fouled by sulfur-reducing bacteria. Maintenance of the sensor is recommended on a monthly basis. Calibration is done using de-ionized water for a zero measurement and by mixing a standard solution of sodium sulfite for a span measurement. Calibration takes about 15 minutes once the standard has been prepared. |
|